Genemate lightcycler semiskirted, lowprofile, 96well pcr. The lightcycler 96 system embodies roches expertise over the last decade in developing and providing highperformance qpcr systems that enable research breakthroughs. System component 2 capillaries, 96 capillaries and capsbox 32 centrifuge adapters with 1 cooling block in an aluminium cooling block lightcycler operator. In the context of the seahorse xfp glycolytic rate assay, the process of converting glucose to lactate. System component 2 lightcycler capillaries 96 capillaries and stoppersbox1 32 lightcycler centrifuge adapters in an aluminum cooling block1 1 lightcycler operators manual 1 lightcycler software package1 cable to connect lightcycler instrument to the computer power cord german power cord u. Keylight is an industryproven blue and green screen keyer. Information on using the quantitect multiplex pcr norox kit with the lightcycler 2. Lightcycler 480 instrument operators manual is correct at the time of printing. The versatile, platebased lightcycler 96 system helps you achieve fast, highly sensitive, and reproducible results for qualitative and quantitative detection of nucleic acids and snp analysis compact and easy to use, the lightcycler 96 system primary is the ideal companion for applications including gene expression analysis, gene detection, mutation detection, methylation analysis. Agilent seahorse xfp glycolytic rate assay kit user guide 9 glossary glycolysis. Alphanumeric grid, colored manufacturing, and the labeling surface. Flexcycler2 pcr thermal cyclers, analytik jena vwr.
These adjustments control the calibration and accuracy. Excellent amplification and homogeneity of reaction products. Make sure the correct thermal block cycler 96well for f plate or 384well block format for g plate is in place. This compact thermal cycler features intuitive programming of temperatures, times, and protocols with readymade templates for ease of viewing, editing, and running protocols. Make sure notch on plate is in the bottom right corner. Place plate in drawer and push drawer until it completely closes. Buffer capacity of the measurement system, comprising the assay medium and xf assay conditions instrument, sensor, labware.
Assays are preplated and dried down for a reaction volume of 20 l on 96well plates and 10 l on 384well plates. A lightcycler probe system consists of a pair of singlestranded fluorescentlabeled oligonucleotides. The core algorithm was developed by the computer film company now framestore and has been further developed. Lightcycler 96 realtime pcr system roche life science. Any unauthorized modification of the instrument entails the invalidity of the guarantee. Turn on the computer linked to the instrument and log on to window xp. Service manual light cycler please note that this is only a. Realtime pcr was done using 30 ng of human dna in each of the 96 block positions. The most popular version of this product among our users is 1. The free 3 hydroxyl group of probe 2 must be blocked.
Chapters 6 and 7 describe programming the minicycler. At present, one of the main medical problems in hospitals is the increasing number. Contact your roche representative for further information. At present, one of the main medical problems in hospitals is the increasing number of nosocomial hospitalacquired infections. Roche lightcycler 96 biotecon diagnostics biotecon. For todays academic researcher labs, the new roche lightcycler 96 system is the optimal midsize, midthroughput realtime pcr solution that conveniently delivers the highest standards expected from a lightcycler system. Biorad icycler thermal cycler manual attachments biorad icycler thermal cycler manual 598 kb. I am using lightcycler 96 for absolute quantification, and want to generate a standard curve, as i am using one reference gene with the 10 different samples with different cdna dilutions such. The lightcycler 96 is a realtime pcr cycler for medium sample throughput.
This manual contains programming information for the agilent technologies n3301a, n3302a, n3303a, n3304a, n3305a, n3306a, and n3307a electronic load modules when installed in an agilent technologies n3300a and n3301a electronic load mainframes. This operators manual contains all the necessary technical information required. System component 1 lightcycler instrument sample carousel for o 1. Roche molecular biochemicals lightcycler operators manual. In preparation for real time polymerase chain reaction applications, small segments of dna or rna are isolated and placed in pcr plates. Chapter 2 describes the physical characteristics of the minicycler. A multitude of different layouts is available for configuration. Thermal cyclers are used to amplify segments of dna via the polymerase chain reaction. We do not recommend performing realtime, multiplex pcr using taqman probes or quantitect assays on the lightcycler system due to the limitations of its optical detection system. Make sure the correct thermal block cycler 96 well for f plate or 384well block format for g plate is in place. The cycler has 4 detection channels, which detect hydrolysis 5nuclease taqman probes either as single color or multiplex samples. Direct questions or concerns regarding the contents of this document to.
This lightcyler 480 instrument quick guide was created by the roche diagnostics corporation commercial education department. The realtime ready focus panels are designed for expression profiling of genes from a variety of. Biorad mycycler thermal cycler marshall scientific. Roche diagnostics corporation commercial education department 9115 hague road p. The lightcycler 480 ii with led is suitable for detection systems with different probe types such as hybridization probes or hydrolysis 5nuclease taqman probes. The lightcycler 480 ii is a realtime pcr cycler for mid to high sample throughput. How to use this manual this manual contains all the information you need to operate your minicycler safely and productively. Press the eject button and wait until the drawer completely opens. Mycycler thermal cycler instruction manual catalog number 1709703 for technical service call your local biorad office or in the u. Service manual 300 watt single input electronic loads agilent technologies model 6060b and 6063b for instruments with serial numbers agilent 6060b us37350101 and up agilent 6063b us37350101 and up for instruments with higher serial numbers, a change page may be included. The labcycler was developed to operate biochemical thermal processes in tubes of the size 0.
Also used to facilitate other temperaturesensitive reactions, the. Biorad mycycler thermal cycler the biorad mycycler thermal cycler, 115v, is a sleek 96well pcr system with a gradient feature used for gene amplification. Small footprint quiet enough to be positioned in the bar contemporary stainless steel finish blends right in. Lightcycler 96 is used by 2 users of software informer. Chapters 35 describe the basics of installing and operating the minicycler. Ii contact addresses manufacturer roche diagnostics ltd. Product specification page 1 96 well lightcycler plate. Product specification page 1 96 well lightcycler plate product description order number 72. Owners manual in order to take advantage of the many interesting features that will provide years of enjoyable amateur radio operation. About this manual the foundry tinder box1 introduction 5 the foundry keylight introduction welcome to this user guide for keylight on after effects. Each labcycler is supplied with a mains cable and an instruction manual. These units will be referred to as electronic load throughout this manual.
Roche applied science the lightcycler system a proven standard for realtime pcr. View and download lg 26lc2r series owners manual online. The lightcycler instrument of roche molecular biochemicals, mannheim, ge rmany, is a thermocycler for the rapid analysis of pcr applications. Taqman fast advanced master mix on the roche lightcycler. With common well matrixes and high or low profile designs that are compatible with thermal cyclers, the pcr plates facilitate rapid segment amplification when manual processing is not wanted. Aug 23, 20 for todays academic researcher labs, the new roche lightcycler 96 system is the optimal midsize, midthroughput realtime pcr solution that conveniently delivers the highest standards expected. Warranty information on warranty conditions are specified in the sales contract. Service manual light cycler please note that this is only. Customers using roche in vitro diagnostic lightcycler kits have to use manual a, marked for in vitro diagnostic use not available in all countries. Compatible to run on any roche or nonroche qpcr insrument. The cyclers feature a large builtin graphical display for easy selection and monitoring of functions. An ideal combination of accuracy, temperature homogeneity, and reproducibility, matched with powerful software so intuitive that it is accessible to any user.
855 824 1086 986 440 480 228 502 86 1651 413 1108 259 1237 517 1309 380 828 502 1168 594 1077 1513 1031 1167 946 129 958 1206 1386 558 673 676 1339 924 1106